Laboratory Tests

 

No-Burn¨ is committed to rigorous product testing and continuous product improvement.  No-Burn¨ products have been tested according to a number of applicable national standards over a variety of substrates.

 

The Testing Standards met include those published by the following organizations:

 

All tests have been conducted by nationally accredited independent tested laboratories such as:

TEST RESULTS

 

NO-BURN¨ PLUS*

1. Class A rating.  Tested per ASTM E-84-05 (Intertek Report No. 3083068)

2. Class A rating.  Tested per ASTM E-84-05 30 minute test (Intertek Report No. 3083068)

3. Class A rating.  Tested per ASTM E-84-05 (7 overcoats of paint) (Intertek Report No. 3104972SAT-001)

 

NO-BURN¨ PLUS Mih* is:

1. UL Classified under UL 723 (R20493)

2. Achieved zero mold growth.  Tested per ASTM D5590-94 (PBR 030819-8-A)

*for details of specific tests conducted on various products, refer to the individual test reports.

 

No Burn Products Summary Tabulation

 

Flame Spread

Smoke

Developed

Substrate

Class

Overcoat

Test Standard

Test Report

NB Plus

5

25

Douglas Fir

A

NA

ASTM E-84-05 (30 min)

Intertek # 3083068 Rev 1 10-4-2005

15

20

Gypsum Board

A

Seven Overcoats Latex Paint

ASTM E-84-05

Intertek # 3104972SAT-001  9-18-2006

NB Plus Mih

5

50-110

Douglas Fir

A

NA

UL 723

UL BMQX.R20493  4-17-2006

 

NB Plus (Room Corner Test)

Pass/Fail

Substrate

Duration of Test

Test Standard

Test Report

Passed

Wood Studs & OSB

30 minutes

NFPA 286

WFCI Report No. 07020B

Passed

OSB

60 minutes

NFPA 286

WFCI Report No. 07020C

Passed

Plywood

30 minutes

NFPA 286